RMON Introduction and Configuration
Software Reference for x310 Series Switches
73.4
AlliedWare Plus
TM
Operating System - Version 5.4.4C
C613-50046-01 REV A
Step 4:
Enable RMON traps.
To ensure that the SNMP trap is sent, you need to enabled RMON traps, and you need
to define a trap host in SNMP. Use the below commands to configure this
functionality:
Note that the resulting log message will be of the form listed below:
awplus#
configure terminal
awplus(config)#
snmp-server
awplus(config)#
snmp-server enable trap rmon
awplus(config)#
snmp-server community public
awplus(config)#
snmp-server host 192.168.2.254 version 2c
public
RMON [1024]: Alarm Index 5 alarm Rising Threshold 5000 alarm
Value 5117 alarm Rising event Index 10 event description
RMON_SNMP