Sflow collector max-datagram-size, Sflow collector max-datagram- size – Allied Telesis AlliedWare Plus Operating System Version 5.4.4C (x310-26FT,x310-26FP,x310-50FT,x310-50FP) User Manual
Page 2102

sFlow Commands
Software Reference for x310 Series Switches
81.8
AlliedWare Plus
TM
Operating System - Version 5.4.4C
C613-50046-01 REV A
sflow collector max-datagram-size
This command sets the maximum size of the sFlow® datagrams sent to the collector.
The no variant of this command resets the maximum-datagram-size to the default.
Syntax
sflow collector max-datagram-size <200-1500>
no sflow collector max-datagram-size
Default
1400 bytes
Mode
Global Configuration
Example
To set the maximum datagram size to 1200, use the command:
Related Commands
show running-config sflow
show sflow
Parameter
Description
<200-1500>
The maximum number of bytes that can be sent in an sFlow
datagram sent from the agent to the collector.
awplus#
configure terminal
awplus(config)#
sflow collector max-datagram-size 1200