Maximum-access-list – Allied Telesis AlliedWare Plus Operating System Version 5.4.4C (x310-26FT,x310-26FP,x310-50FT,x310-50FP) User Manual
Page 927

IPv4 Software Access Control List (ACL) Commands
Software Reference for x310 Series Switches
C613-50046-01 REV A
AlliedWare Plus
TM
Operating System - Version 5.4.4C
35.41
maximum-access-list
Sets the maximum number of filters that can be added to any access-list. These are access-
lists within the ranges <1-199>, <1300-1999> and <2000-2699> and named standard and
extended access-lists.
The no variant of this command removes the limit on the number of filters that can be
added to a software access-list
Syntax
maximum-access-list <1-4294967294>
no maximum-access-list
Mode
Global Configuration
Example
To set the maximum number of software filters to 200:
Parameter
Description
<1-4294967294>
Filter range.
awplus#
configure terminal
awplus(config)#
maximum-access-list 200