JLG 1500SJ Service Manual User Manual

Page 463

Advertising
background image

SECTION 6 - JLG CONTROL SYSTEM

3121262

– JLG Lift –

6-11

FUNCTION CUTOUT:
17*

0

1

2

3

NO: No drive cutout.

BOOM CUTOUT: Boom function cutout while driving above elevation.

DRIVE CUTOUT: Drive cutout above elevation.

DRIVE CUT E&T: Drive cutout above elevation and tilted.

0

* Only visible under certain market selections.

* Certain market selections will limit function cutout options or alter default setting.

GROUND ALARM:
18*

0

1

2

3

NO: No ground alarm installed.

DRIVE: Travel alarm sounds when the drive function is active (Option).

DESCENT: Descent alarm sounds when lift down is active (Option).

MOTION: Motion alarm sounds when any function is active (Option).

0

* Certain market selections will alter default setting.

OSCILLATING AXLE:
19

0

1

NO: No oscillating axle system installed.

YES: Oscillating axle system installed.

1

TEMPERATURE:
20*

0

1

CELSIUS: Celsius unit selection.

FAHRENHEIT: Fahrenheit unit selection.

1

* Certain market selections will alter default setting.

LEVELING MODE:
21

0

1

LIFT: Platform leveling during lift only.

ALL: Platform leveling during all functions.

1

CLEARSKY:
22

0

1

NO: ClearSky Telematics system not installed.

YES: ClearSky Telematics system installed.

0

1001128802-1

Table 6-2. Machine Configuration Programming Information

Configuration Digit

Number

Description

Default

Number

Advertising