SECTION 6 - JLG CONTROL SYSTEM

6-74

– JLG Lift –

3121262

13. Hit enter. The number displayed will be the value

that the crack point is set to. The screen will show:

14. Hit Enter. The screen will read:

15. Repeat steps 10 thru 12 for the Lift Down function.

16. After completing all the Tele Calibrations, hit ESC

twice to go back to CALIBRATIONS.

6.15 CALIBRATING TELESCOPE CRACK POINT

1. Position the Platform/Ground select switch to the

Platform position.

2. Plug the analyzer into the connector at the base of

the platform control box.