SECTION 6 - JLG CONTROL SYSTEM

6-102

– JLG Lift –

3121262

Press Enter. The screen will read:

31. Telescope to the yellow witness mark (controller will

be close - operator must position the pointer to cen-
ter line on decal within 0.25" [6 mm]) for Calibration
Position 9.

When the boom is in the proper position, hit Enter.
The screen will read:

When Position 9 calibrating is complete, the screen
will read:

Figure 6-29. Boom Sensor Calibration Position 9