JLG 1500SJ Service Manual User Manual

Page 542

Advertising
background image

SECTION 6 - JLG CONTROL SYSTEM

6-90

– JLG Lift –

3121262

2. Plug the analyzer into the connector inside the

Ground control box.

3. Pull out the Emergency Stop switch and start the

engine.

4. The analyzer screen should read:

5. Use the arrow button to reach ACCESS LEVEL 2. Hit

Enter.

6. Enter the Access Code, 33271.

7. Go to the CALIBRATIONS menu and hit ENTER.

8. Go to the JIB LVL UP CRKPT Screen. Hit ENTER.

9. CALIBRATE? prompt should appear. Hit ENTER

again.

10. You will hear engine go to 1800 rpm.

11. Using UP ARROW, increase the value until you see

the jib level movement.

12. Hit ENTER again. CAL. COMPLETE message

should appear

13. Engine should again return to idle.

14. Hit ESC should return to JIB LVL UP CRKPT screen.

15. Hit RIGHT ARROW to get to the JIB LVL DN CRKPT

screen. Hit ENTER.

16. CALIBRATE? prompt should appear. Hit ENTER

again.

17. You will hear engine go to 1800 rpm.

Using UP ARROW, increase the value until you see the jib
level down movement.

Hit ENTER again. CAL. COMPLETE message should
appear

Engine should again return to idle.

Hit ESC to exit.

Cycle power to the machine.