3 machine orientation when setting function speeds, Test notes, Test notes -18 – JLG 1500SJ Service Manual User Manual

Page 470

Advertising
background image

SECTION 6 - JLG CONTROL SYSTEM

6-18

– JLG Lift –

3121262

6.3 MACHINE ORIENTATION WHEN SETTING

FUNCTION SPEEDS

LIFT UP, from platform control, lowest elevation up to
maximum elevation, boom retracted, jib retracted.

LIFT DOWN, from platform control, maximum elevation
down to minimum elevation, boom retracted, jib retracted.

JIB LIFT UP, from platform control, lowest jib elevation up
to maximum jib elevation, boom retracted, jib retracted.

JIB LIFT DOWN, from platform control, maximum jib ele-
vation down to minimum jib elevation, boom retracted, jib
retracted.

SWING RIGHT(Max),360 Degrees, from platform control,
boom approximately 45° elevation, boom retracted, jib
retracted.

SWING LEFT(Max), 360 Degrees, from platform control,
boom approximately 45° elevation, boom retracted, jib
retracted.

TELESCOPE OUT, from platform control, boom @ 20
degrees, 500 lb. capacity selected.

TELESCOPE IN, from platform control, boom @20
degrees, 500 lb. capacity selected.

JIB TELESCOPE IN, from platform control, boom hori-
zontal, jib horizontal, 500 lb. capacity selected.

JIB TELESCOPE OUT, from platform control, boom hori-
zontal, jib horizontal, 500 lb. capacity selected.

DRIVE FORWARD (Max), high speed - low torque set-
ting, drive 200 ft. front wheels to front wheels. Timed after
machine has obtained maximum speed.

DRIVE REVERSE (Max), high speed - low torque setting,
drive 200 ft. front wheels to front wheels Timed after
machine has obtained maximum speed.

DRIVE FORWARD (Creep Max), high torque - low speed
setting, platform speed knob at full creep

DRIVE REVERSE (Creep Max), high torque - low speed
setting, platform speed knob at full creep

DRIVE FORWARD (Elevated Max - Boom Beyond
Transport)
, high speed - low torque setting, platform
speed knob out of creep, Lift boom above transport, drive
forward 50 ft.

DRIVE REVERSE (Elevated Max - Boom Beyond Trans-
port)
, high speed - low torque setting, platform speed
knob out of creep, Lift boom above transport, drive back-
ward 50 ft.

Test Notes

1. Personality settings can be adjusted anywhere

within the adjustment range in order to achieve opti-
mum machine performance.

2. Stop watch should start when the function is acti-

vated.Not with the controller or switch.

3. Unless noted, function speeds should be measured

from platform.

4. Platform speed knob must be at full speed (fully

clockwise).

5. All test should be done with the oil temp above 100°

F (38° C).

Advertising