MAIN LIFT:

ACCEL X.Xs

Displays/adjusts main lift acceleration 0.1 to 5.0 sec

1

DECEL X.Xs

Displays/adjusts main lift deceleration 0.1 to 3.0 sec

1

MIN UP XX%

Displays/adjusts minimum main lift up
speed

0 to 60%

20

MAX UP XX%

Displays/adjusts maximum main lift
up speed

0 to 100%

60

75-100 (see orientation)

CREEP UP XX%

Displays/adjusts maximum main lift
up speed

0 to 65%

50

NOTE: used when creep switch on
pump pot is active

MIN DOWN XX%

Displays/adjusts minimum main lift
down speed

0 to 60%

10

MAX DOWN XXX%

Displays/adjusts maximum main lift
down speed

0 to 100%

60

85-110 (see orientation)

CREEP DOWN XX%

Displays/adjusts maximum main lift
down speed

0 to 75%

45

NOTE: used when creep switch on
pump pot is active

SWING:

ACCEL X.Xs

Displays/adjusts swing acceleration

0.1 to 5.0 sec

2

DECEL X.Xs

Displays/adjusts swing deceleration

0.1 to 3.0 sec

1.5

MIN LEFT XX%

Displays/adjusts minimum swing left
speed

0 to 50%

40

MAX LEFT XXX%

Displays/adjusts maximum swing left
speed

0 to 100%

65

115-125 (see orientation)

CREEP LEFT XX%

Displays/adjusts maximum swing left
speed

0 to 65%

52

NOTE: used when creep switch on
pump pot is active

MIN RIGHT XX%

Displays/adjusts minimum swing right
speed

0 to 50%

40

MAX RIGHT XXX%

Displays/adjusts maximum swing
right speed

0 to 100%

60

115-125 (see orientation)

CREEP RIGHT XX%

Displays/adjusts maximum swing
right speed

0 to 65%

47

NOTE: used when creep switch on
pump pot is active

Table 6-4. Machine Personality Settings and Function Speeds