SECTION 6 - JLG CONTROL SYSTEM
3121262
– JLG Lift –
6-69
4. The analyzer screen should read:
5. Use the arrow button to reach ACCESS LEVEL 2. Hit
Enter.
6. Enter the Access Code, 33271.
7. Use the arrow button to reach PERSONALITIES
adjust the following personalities. Refer to the Per-
sonality Ranges/Defaults table for proper setting val-
ues.
Basket Level Up Min
Basket Level Up Max
Basket Level Down Max
Jib Up Min
Jib Down Min
8. Recycle EMS.
STEP 2: BLEEDING THE PLATFORM VALVES
1. Position the Platform/Ground select switch to the
Ground position.
2. Plug the analyzer into the connector inside the
Ground control box.
3. Pull out the Emergency Stop switch and start the
engine.