Troubleshooting chart - electrical system

TROUBLESHOOTING AT THE BATTERY

Battery is
not being
charged
sufficiently
or at all, or
is being dis-
charged too
rapidly.

Battery is
overcharged.

Malfunction

Indication

Possible cause

Remedial action

Poor connections, open
circuit or contact resist-
ance in charging circuit,
short-circuit in line.

Acid level too high.

Draw off excess acid
with hygrometer.

Acid emerging at
cell plugs.

Check voltage regulator,
renew if defective.

Defective voltage regu-
lator.

Terminal voltage
permanently above
16.5 V at 12 V
nom inal voltage,
acid density above
1.285 kg/l,
battery acid boils.

Charge voltage too high.

Battery capacity is too
low.

Check voltage regulator,
renew if necessary.

Install a larger-capacity
battery. As a temporary
measure, discharge the
battery at intervals, e.g.
by switching on con-
sumers without running
the engine.

Recharge the battery.

Charging rate too low
(especially in winter).

Battery capacity too
large.

Install a smaller battery.

Defective voltage regu-
lator (e.g. overheated/
overloaded).

Renew the voltage re-
gulator.

Recharge battery at
low current (app. 1/40
of nom inal capacity
in Amps) for about 50
hours. (Only possible if
suplhatising not yet too
far advanced.) Other-
wise: renew battery.

Battery capacity has
dropped severely due
to severe discharge for
a lengthy period (grey-
white coating on plates
(“sulphatising”).

Battery defective (inter-
nal short circuits).

Renew the battery.

Even shortly after
charging, the ter-
minal voltage drops
rapidly to 7 V on
sys tems with 12 V
nominal voltage.

Eliminate open circuit,
clean posts and clips,
tighten loose terminals.