4 - ELECTRICAL MOTOR

1. Press button 7 "SETUP“.

2. Press button 5 “PASSWORD”.

Using the remote control buttons to enter the pass-
word "Level 2":3522.

NOTE: password above allow to choose the options shown on the

screen.

Once the correct password is accepted the display
shown “OK”.

3. Press button 9 “ESC”.

Repeat the above steps if “NO” appear on the dis-
play.

4. Press button 3 ”EXTRA”

5. Press button 1 "OPTIONAL"

6. Press button 4 “EL.MOT”.

7. Press button 1 2,2 KW for 220- 240 Volt 50HZ.

8. Press button 2 1,2 KW” for 110 Volt 60HZ.

Press 5 times button 9 Esc to escape

5 - LAMP ON OUTRIGGER

1. Press button 7 "SETUP“.

2. Press button 5 “PASSWORD”.

Using the remote control buttons to enter the pass-
word 6661.

NOTE: password above allow to choose the options shown on the

screen.

Once the correct password is accepted the display
shown “OK”.

3. Press button 9 “ESC”.

Repeat the above steps if “NO” appear on the dis-
play.

4. Press button 3 ”EXTRA”

5. Press button 1 "OPTIONAL".

6. Press button 5 “LAMPS”.

7. Press button 1 for Lamps continuously ON. Press

button 1 for lamps continuously ON with outrigger
on the ground and full work area active, while blink-
ing in restricted work area.

8. Press button 2 for Lamps Blinking. Press button 2 for

lamps blinking with outrigger on the ground while
lamps ON in restricted work area.

Press 5 times button 9 to Esc to escape