Bms fault codes – JLG X20JP - X600AJ Service Manual User Manual

Page 297

Advertising
background image

SECTION 6 - JLG CONTROL SYSTEM

3121623

– JLG Lift –

6-81

BMS fault codes

In any case, when the display shows a fault code of the
BMS, we suggest to connect Rahmino software to the
machine.

EXAMPLES OF BMS ERROR

02 – UNEXPECTED VOLTAGE:

In case of one cell reach 3650 mV the BMS will disconnect
the lithium pack and the system will show the “UNEX-
PECTED VOLTAGE” error. This could be caused by a fail-
ure on BMS that doesn’t recognize one cell or cannot
connect it to the discharging resistance.

05 - OVERCURRENT CHARGE:

While the lithium pack is warm and one cell is already at
the maximum value, when the battery charger is suddenly
connected for a while one impulse of current will feed the
pack, in this case could happen that the system will show
the “OVERCURRENT CHARGE” error.

Table 6-12.

CODE

MEANING

01

SYSTEM CONFIGURATION ERROR

02

UNEXPECTED VOLTAGE

03

UNEXPECTED TEMPERATURE

04

OVERCURRENT DISCHARGE

05

OVERCURRENT CHARGE

06

PRE-CHARGE ERROR

07

NO 12 VOLT SUPPLY

08

NO -12 VOLT SUPPLY

09

BATTERY OVERTEMPERATURE

10

ELECTRONICS OVERTEMPERATURE

11

BAD TEMP SENSOR AUTO SHUT OFF
MODE

12

ALL TEMP SENSOR BROKEN

13

BROKEN TEMPERATURE SENSOR
DETECTED

14

GRUNDING FAULT ERROR

15

NO BOOTLOADER ERROR

16

SECOND PROTECTION

17

WATCHDOG ERROR

18

POWER BOARD ALARM

19

I2C MODULE NOT READY

20

I2C TX ERROR

21

I2C RX ERROR

22

I2C RX ERROR 2

23

AD ERROR

99

GENERAL ERROR