SECTION 6 - JLG CONTROL SYSTEM

6-32

– JLG Lift –

3121623

POSM3 B

ON

Do not consider

OFF

Do not consider

POSM4 A

ON

Do not consider

OFF

Do not consider

POSM4 B

ON

Do not consider

OFF

Do not consider

R.C. BASKET

ON

The remote control is in the support in basket

OFF

The remote control is not in the support in basket

INCLIN. X

0

Indicates the inclination of the machine on the X axis in tenth of degrees
(accelerometer A)

0

Indicates the inclination of the machine on the X axis in tenth of degrees (accel B)

INCLIN. Y

0

Indicates the inclination of the machine on the Y axis in tenth of degrees (accelerom-
eter A)

0

Indicates the inclination of the machine on the Y axis in tenth of degrees (accel B)

LOAD

94

Indicates the weight in Kg in the basket

POS. 1E2

0

Do not consider

POS. 3

2398

Indicates the opening of the 3 arm cylinder in tenths of a millimetre

ROTATION A

180

Do not consider

MOTOR RPM Diesel

Only

2200

Indicate the engine RPM

CURRENT A

2,5

Indicates (in tenth of mA) the current ECM1-2 is sending to the aerial part
proportional valve or to the left-side undercarriage proportional valve (values less
that 5 not relevant)

CURRENT B

45,3

Indicates (in tenth of mA) the current ECM1-2 is sending to the right-side
undercarriage proportional valve (values less that 5 not relevant)

CURRENT C

0

Do not consider

TEMPERAT.

37,6

Indicates the temperature of the control module in C°

SUPPLY (V)

12,1

Indicates the batteries voltage, or the output voltage from the battery charger

BATTERY %

100

Only for Lithium version: indicates the % level of charge of the pack