SECTION 6 - JLG CONTROL SYSTEM

3121623

– JLG Lift –

6-31

MOTOR PRES

To consider only for X20JP

- X600 AJ

ON

The engine oil pressure is inadequate (emergency condition – engine turns off)

OFF

The engine oil pressure is OK

START M.EL

ON

The ground button for electric motor start is pressed

OFF

The ground button for electric motor start is released

GND/BASKET

ON

The control position key selector is positioned on “basket”

OFF

The control position key selector is positioned on “ground”

MICROJIB A

ON

The JIB is closed – the control switch is released and “A” line is closed

OFF

The JIB is open – the control switch is pressed and “A” line is open

MICROJIB B

ON

The JIB is closed – the control switch is released and “B” line is closed

OFF

The JIB is open – the control switch is pressed and “B” line is open

PEDAL

ON

The pedal is pressed– the pedal electric line is closed

OFF

The pedal is released – the pedal electric line is open

FREE B

Do not consider this signal

EM.BASK.A

ON

The stop button on remote control in basket is released – “A” line is closed

OFF

The stop button on remote control in basket is pressed or the ground remote
control is disconnected – “A” line is open

EM.BASK. B

ON

The stop button on remote control in basket is released – “B” line is closed

OFF

The stop button on remote control in basket is pressed or the ground remote
control is disconnected – “B” line is open

POSM1 A

ON

Do not consider

OFF

Do not consider

POSM1 B

ON

Do not consider

OFF

Do not consider

POSM2 A

ON

Do not consider

OFF

Do not consider

POSM2 B

ON

Do not consider

OFF

Do not consider

POSM3 A

ON

Do not consider

OFF

Do not consider

X17JP - X20JP - X500AJ - X600AJ