3 function pump, Seal kit replacement instruction, Main operations – JLG X20JP - X600AJ Service Manual User Manual

Page 199

Advertising
background image

SECTION 5 - HYDRAULICS

3121623

– JLG Lift –

5-21

5.3 FUNCTION PUMP

HYDRAULIC PUMP REPAIR

SEAL KIT REPLACEMENT INSTRUCTION

65602813 POMPA PLP10.4-86E1/10.4 D/FS-EL
VZN

65602807 POMPA PLP10.3,15-86E1/10.3,15 D/
FS-EL-D VZN

CASAPPA

Main operations:

GENERAL SUGGESTION

1. Check the parts have not been damaged during the

shipment.

2. Work in a clean area.

3. Clean with solvent (except the seals) and air dry all

components before assembling.

4. Pay attention not to damage the machined surfaces.

5. The components need to be fitted in place without

forcing them. If too much force is required, it is due a
bad clearances issues.

6. When hand pressure is not enough, use only mallet

and never hammer.

7. Respect the tightening torque for bolts.

Advertising