SECTION 6 - JLG CONTROL SYSTEM

6-66

– JLG Lift –

3121623

SETUP 6 - LOAD SENSING SYSTEM (LSS
CALIBRATION)

This menu allows the Calibration Menu is used with Plat-
form weight.

A NEW LOAD CELL OR A NEW LSS MODULE WILL ACT AS IF IT IS
WITHOUT AREA UNTIL THE FOLLOWING PROCEDURE IS PER-
FORMED. THE UPPER FRAME COULD INTERFER WITH THE OUT-
RIGGERS.

THE LOAD SENSING SYSTEM REQUIRES PERIODIC
FUNCTION. VERIFICATION

.

Empty the platform to allow the Load Sensing System to
record its weight during calibration.

Remove the remote control from the basket and keep it on
hand.

1. Press button 6 "SERVICE"

2. Press button 7 "SETUP“.

3. Press button 5 “PASSWORD”.

Using the remote control buttons to enter the pass-
word "Level 2": 6138

Once the correct password is accepted the display
shown “OK”.

4. Press button 9 “ESC”.

Repeat the above steps if “NO” appear on the dis-
play.

5. Press button 6 “LOADSENS” to enter in LOADSENS

SETUP.

6. Press button 1 “SET 0KG” and wait for about 5 sec-

onds.