SECTION 5 - HYDRAULICS

5-10

– JLG Lift –

3121623

Magnetic Sensor Removing

1. Pull out retain clip with pliers.

2. Pull out the spacer.

3. Pull out the magnet.

4. Pull out the other spacer.

Threaded Piston Disassembling

PROTECT THE FINISH ON THE ROD AT ALL TIMES. DAMAGE TO
THE SURFACE OF THE ROD CAN CAUSE SEAL FAILURE.

Fix the rod into the vice.

NOTE: Before attempting to disassemble the piston remove any

accessible seals.

NOTE: Apply heat to break the bond of the sealant between the

piston and the rod before the piston can be removed.

WARM THE SURFACE INDICATED MAX 300°C

Avoid overheating, or the parts may become distorted or
damaged.

Apply sufficient torque for removal while the parts are still
hot. The sealant often leaves a white, powdery residue on
threads and other parts, which must be removed by
brushing with a soft brass wire brush prior to reassembly.