SECTION 6 - JLG CONTROL SYSTEM

6-104

– JLG Lift –

3121623

Seventh Group (BMS Status)

The following parameters are internal the BMS, so we can-
not manage them.

However their status can be helpful at the BMS supplier in
case of failure.

Figure 6-105.

Power control: Microcontroller supply ON/OFF.

Heating control: Heating control ON/OFF.

Overcharge (2

nd

prot): Secondary protection overcharged

reached.

Overdischarge (2

nd

prot): Secondary protection overdis-

charged reached.

Balancing active: Balancing active on at least one cell.

Parameterization mode: Parameterization mode ON/OFF.

Supervision +12V: +12 Volt confirmation.

Supervision -12V: - 12 Volt confirmation.