SECTION 6 - JLG CONTROL SYSTEM

6-74

– JLG Lift –

3121623

The Inverter fault codes are always prefaced by “05A” ini-
tials, for example 05A79 or 05A38, etc.

IMPORTANT: BEFORE STARTING THE DIAGNOSIS
WITH FAULT RESEARCH, CONTROL THE VOLTAGE
LEVEL OF THE BATTERY PACK.

76

Key off shorted

Cause:

Key-off signal is low at key-on.

Solution:

Check the 12 volt battery and its connexions, check the DC-DC and its connexions, check
the inverter connexions; replace the inverter.

77

Contactor open

Cause:

Main contactor is not closed even if fed by the inverter

Solution:

Check the main contactor

77

Tiller Error

Cause:

Input mismatch between hard & soft switch input and tiller input.

Solution:

Check the Can Bus Line connexions.

78

VACC not OK

Cause:

Solution:

Usually it is a temporary anomaly due to a particular working condition. In case the anomaly
persists replace the inverter.

79

Incorrect start

Cause:

Starting procedure not correct

Solution:

Control the electric connections. Usually it is a temporary anomaly due to a particular work-
ing condition. In case the anomaly persists replace the inverter.

80

Emergncy MDI CAN code alarm

Cause:

Emergency MDI code alarm

Solution:

Check the inverter feeds

82

Encoder Error

Cause:

Problem on the encoder

Solution:

Check the connexions from the inverter to the electric motor; replace the inverter

86

Pedal wire KO

Cause:

Solution:

Usually it is a temporary anomaly due to a particular working condition. In case the anomaly
persists replace the inverter.

86

Pos EB shorted

Cause:

Output not correct

Solution:

Check the inverter connexions; replace the inverter

89

Power MOS shorted

Cause:

Short circuit in the power mosfets

Solution:

Replace the inverter

93

Wrong set batt

Cause:

With supply ON, the control test detected batteries not in conformity.

Solution:

Replace the batteries with the original ones supplied by JLG.

94

Current sensor KO

Cause:

Max current setup procedure active.

Solution:

Contact JLG after sales dept.

96

Analog Input

Cause:

Problem on the A/D conversion of uC

Solution:

It should be a temporary error, if the problem occurs permanently replace the inverter

99

Check up needed

Cause:

Solution:

Contact JLG after sales dept.

Table 6-10.