5 pressure setting procedure, Control valve (chassis functions), Control valve left side (chassis functions) – JLG X20JP - X600AJ Service Manual User Manual

Page 213: Automatic reductions drive speed

Advertising
background image

SECTION 5 - HYDRAULICS

3121623

– JLG Lift –

5-35

5.5 PRESSURE SETTING PROCEDURE

Cold temperatures have a significant impact on pressure
readings. JLG Industries Inc. recommends operating the
machine until the hydraulic system has warmed to normal
operating temperatures prior to checking pressures. JLG
Industries Inc. also recommends the use of a calibrated
gauge. Pressure readings are acceptable if they are within
± 5% of specified pressures.

Control Valve (Chassis functions)

1. Machine completely closed.

2. Install the pressure gauge at the port marked MA

Figure xx.

3. Activate the function outrigger IN on remote control.

4. Verify that the pressure is as on Table below.

Figure 5-5.

To adjust the relief valve, turn clockwise to increase, turn
counterclockwise to decrease the pressure.

Automatic reductions drive speed (X17JP-
X500AJ only)

Adjust pressure reducing valve (only X17JP - X500AJ)

1. Adjust the pressure when the machine is

completely closed.

2. Install the pressure gauge at the port 5.

3. Activate the function outrigger IN on remote control

1.

4. Verify that the pressure is as on Table below.

5. Pressure adjust on relief valve point 6

Control Valve Left Side (Chassis functions)

Model Pressure

Port

Pressure setting

Bar

PSI

X17JP

X500AJ

MA

165

2400

X20JP

X600AJ


0,2

A

3,23,2

B B

B B

APPOGGIO_POST

Automatic reductions drive speed

Model

Pressure

Port

Function Pressure

setting

Bar

PSI

X17JP

X500AJ

Point 5

Function

Outrigger IN

26

380


0,2

A

3,23,2

B B

B B

APPOGGIO_POST

Advertising