SECTION 3 - CHASSIS & TURNTABLE

3121623

– JLG Lift –

3-71

GENERAL NOTES

Technical data

1)

These values are intended as an approximate guide.

Themax.marking on the dipstick is the deter-mining factor.

2)

Depending on model (see maintenance charts).

3)

Exceeding these limits causes engine breakdown.

Tightening torques

Type

1B40

Design

Air-cooled four-stroke diesel engine

Combustion system

Direct injection

Number of cylinders

1

Bore / stroke

mm

88 / 76

Displacement

cm3

462

Lubricating oil capacity without oil sump with oil
sump

l, approx.
l, approx.

1.5 1)
3.2 1)

Difference between “max” and “min” levels without
oil sump with oil sump

l, approx.
l, approx.

0.8 1)
2.2 1)

Lubricating oil consumption (after running in)

max.

1% of fuel consumption

at full load

Lubricating oil pressure (oil temperature 100 °C)

approx.

2.5 bars at 3000 r.p.m.

Direction of rotation, power take-off end

anti-clockwise

Valve clearance 10 - 30 °C
Inlet and exhaust valve

mm

0.10

or automatically 2)

Max. tilt angle in operation, in direction

Flywheel 25° down 3) all other directions

35°3)

Weight (incl. fuel tank, air-cleaner, exhaust
silencer, recoil starter and electric starter)

kg,

approx.

55

Battery capacity

Amp/h

max. 12 V / 60 Amp/h

Item

Nm

Oil drain plug

50