6.10 CURRENTS

From the SERVICE menu, pressing button 5”CURRENT”
accesses the menu CURRENT to adjust the parameter
settings in order to achieved optimum machine perfor-
mance.

1. Press button 7 “SETUP”.

2. Press button 5 “PASSWORD”.

Using the remote control buttons to enter the pass-
word 1883.

NOTE: password permit to change all CURRENT Settings.

Once the correct password is accepted the display
shown “OK”.

3. Press button 9 “ESC” two times.

NOTE: Repeat the above steps if “NO” appear on the display.

4. Press button 5 “CURRENT” to enter in menu current

setting.

Use buttons 1 PREV. and 2 NEXT to scroll the vari-
ous functions.

5. Use buttons 7 UP and 8 DOWN to adjust the values.

6. Press button 3 SAVE to save

NOTE: EVERY TIME THE RAMP VALUE GETS MODIFIED

BUTTON 3 TO SAVE MUST BE PRESSED; OTHER-
WISE THE MODIFICATION IS NOT ACTIVATE.

NOTE: Personality settings can be adjusted within the adjustment

range in order to achieve optimum machine performance.

NOTE: Refer to Table 6.8, Time range (sec) for recommended set-

tings.