13

Parameter reference

13.2

Parameters of the communication module for slot MXI1

108

Lenze · E94AYCET communication module (EtherCAT®) · Communication Manual · DMS 9.0 EN · 02/2014 · TD17

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C13850

C13851

C13852

Parameter | Name:

C13850 | All words to master

Data type: UNSIGNED_16

Index: 10725 = 0x29E5

Display of the process data words (subcodes 1 ... 32) which are transferred from the communication module to the

master.

Only those which are configured are valid.
Display area

(min. value | unit | max. value)

0

65535

Subcodes

Info

C13850/1
...
C13850/32

Read access  Write access  CINH  PLC-STOP  No transfer  PDO_MAP_RX  PDO_MAP_TX  COM  MOT

Parameter | Name:

C13851 | All words from master

Data type: UNSIGNED_16

Index: 10724 = 0x29E4

Display of the process data words (subcodes 1 ... 32) which are transferred from the master to the communication

module.

Only those which are configured are valid.
Display area

(min. value | unit | max. value)

0

65535

Subcodes

Info

C13851/1
...
C13851/32

Read access  Write access  CINH  PLC-STOP  No transfer  PDO_MAP_RX  PDO_MAP_TX  COM  MOT

Parameter | Name:

C13852 | All words to standard device

Data type: UNSIGNED_16

Index: 10723 = 0x29E3

Display of the process data words (subcodes 1 ... 32) which are transferred from the communication module to the

standard device.
Display area

(min. value | unit | max. value)

0

65535

Subcodes

Info

C13852/1
...
C13852/32

Read access  Write access  CINH  PLC-STOP  No transfer  PDO_MAP_RX  PDO_MAP_TX  COM  MOT