5

Installation

5.2

Electrical installation

26

Lenze · E94AYCET communication module (EtherCAT®) · Communication Manual · DMS 9.0 EN · 02/2014 · TD17

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

5.2.3

EtherCAT connection

The EtherCAT connection is established via the RJ45 sockets X246 (IN) and X247 (OUT).
A standard Ethernet patch cable is suitable for connecting the communication module to the

EtherCAT fieldbus.

Specification of the Ethernet cable

( 27)

Pin assignment of the RJ45 sockets

Tip!
The EtherCAT interfaces are provided with an auto auto MDIX function. This function

adjusts the polarity of the RJ45 interfaces so that a connection can be established

irrespective of the polarity of the opposite EtherCAT interface and irrespective of the type

of cable used (standard patch cable or crossover cable).

Note!

In order to prevent damage to the RJ45 socket, plug or remove the Ethernet cable

connector straight (at a right angle) into/from the socket.

RJ45 socket

Pin

Signal

E94AYCXX004C

1

Tx +

2

Tx -

3

Rx +

4

-

5

-

6

Rx -

7

-

8

-

Advertising