C14885 | clear process data, C14892 | process data mode, C14899 | station alias – Lenze E94AYCET User Manual

Page 129: C14900 | firmware: product type, C14892, C14899, C14885, Is ta, 13 parameter reference

Advertising
background image

Lenze · E94AYCET communication module (EtherCAT®) · Communication Manual · DMS 9.0 EN · 02/2014 · TD17

129

13

Parameter reference

13.3

Parameters of the communication module for slot MXI2

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C14885

C14892

C14899

C14900

Parameter | Name:

C14885 | Clear process data

Data type: UNSIGNED_8

Index: 9690 = 0x25DA

This code serves to set which process data the slave is to process for maintaining internal communication when the

EtherCAT has exited the "Operational" state.
Selection list

(Lenze setting printed in bold)

Info

0 Use of most recent master PDOs
1 PDOs are set to the value '0'

Read access  Write access  CINH  PLC-STOP  No transfer  PDO_MAP_RX  PDO_MAP_TX  COM  MOT

Parameter | Name:

C14892 | Process data mode

Data type: UNSIGNED_8

Index: 9683 = 0x25D3

Mode selection for a time optimisation of the process data transfer

This code is only evaluated if "Distributed clocks" are used.

Synchronisation with "Distributed Clocks" (DC) ( 35)

Process data mode ( 39)

Selection list

(Lenze setting printed in bold)

Info

0 Optimised mode

This mode leads to a reduction of the dead time by one

EtherCAT cycle.

Preconditions:

• The EtherCAT frame generated by the master has a

low jitter and is sent within a window of 320 μs after

the Sync0 and shortly before the next Sync0 event.

• The EtherCAT cycle time must be 1 ms.

1 Deterministic mode

This mode is the standard mode. It does not support a

time optimiesation of the process data transfer.

The actual values are copied to the EtherCAT interface

with the next Sync0 event.

Read access  Write access  CINH  PLC-STOP  No transfer  PDO_MAP_RX  PDO_MAP_TX  COM  MOT

Parameter | Name:

C14899 | Station alias

Data type: UNSIGNED_16

Index: 9676 = 0x25CC

This code serves to set a station alias.

In order to use a station alias, you must select a value > "0".

• The station alias must only be set if the node is part of a "hot connect" group.

• The station alias must be unambiguous and must only be assigned once within the EtherCAT network.

• Use the same station alias in the EtherCAT master and in the slave.

Define station alias ( 34)

Setting range

(min. value | unit | max. value)

Lenze setting

0

32767 0

Read access  Write access  CINH  PLC-STOP  No transfer  PDO_MAP_RX  PDO_MAP_TX  COM  MOT

Parameter | Name:

C14900 | Firmware: Product type

Data type: VISIBLE_STRING

Index: 9675 = 0x25CB

The code contains a string with a length of 8 bytes.

The following identification code is output: "E94AFCET".

Read access  Write access  CINH  PLC-STOP  No transfer  PDO_MAP_RX  PDO_MAP_TX  COM  MOT