3 protocol data, 4 communication time, Protocol data – Lenze E94AYCET User Manual

Page 19: Communication time, 4technical data

Advertising
background image

Lenze · E94AYCET communication module (EtherCAT®) · Communication Manual · DMS 9.0 EN · 02/2014 · TD17

19

4

Technical data

4.3

Protocol data

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

4.3

Protocol data

4.4

Communication time

Parameter data (SDO)
The communication time for parameter data is the time between the transmission of an SDO

request and the arrival of the corresponding response.
The processing time in the drive is approx. 30 ms + 20 ms tolerance (typical)
Some codes may require a longer processing time (see reference manual/»Engineer« online help for

Servo Drive 9400).

Process data (PDO)
The communication time for process data is the time between the reception of a PDO with setpoints

and the return of a PDO with the current actual values.
The communication times for process data depend on the ...

• processing time in the drive (interval time of the application task, process data mode);
• Runtime on the fieldbus (frame length, number of nodes, PDO update time, instant of

transmission of the EtherCAT frame);

• Use of the "Distributed clocks" (DC) functionality for synchronised operation.

Synchronisation with "Distributed Clocks" (DC)

( 35)

Area

Values

Process data

1 ... 32 process data words for each direction

(max. 64 bytes, 16 bits / word)

Parameter data (mailbox size for CoE

transfer)

Max. 128 bytes