Commissioning

6.2

Configuring the controller (EtherCAT master)

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

6.2.3

Configuring process data

Servo Drives 9400 support the configuration of max. 32 process data words (max. 64 bytes) per

direction.
The process data configuration is determined during the initialisation phase of the master (PDO

mapping).
The process data configuration is specifically predefined in the device description file for each

application.
The process data length can be adapted by the user, if required.

6.2.4

Determining the cycle time

The process data objects (PDO) are transmitted cyclically between the EtherCAT master and the

slaves (drives).
The cycle time is set by means of the EtherCAT configuration software.