9parameter data transfer – Lenze E94AYCET User Manual

Page 77

Advertising
background image

Lenze · E94AYCET communication module (EtherCAT®) · Communication Manual · DMS 9.0 EN · 02/2014 · TD17

77

9

Parameter data transfer

9.2

Reading and writing parameters

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

SDO Download Response
Detailed breakdown of the data for a "SDO download response":

SDO frame area

Data field

Data type / length

Value / description

Mailbox header

Length

WORD

2 bytes

0x0A: Length of the mailbox service data

Address

WORD

2 bytes

Station address of the source if an EtherCAT

master is the initiator.

Station address of the target if an EtherCAT slave

is the initiator.

Channel

WORD

6 bits

(0 ... 5)

0x00: Reserved

Priority

2 bits

(6, 7)

0x00: Lowest priority

...

0x03: Highest priority

Type

4 bits

(8 ... 11)

0x03: CANopen over EtherCAT (CoE)

Reserved

4 bits

(12 ... 15)

0x00

CANopen header Number

WORD

9 Bits

(0 ... 8)

0x00

Reserved

3 bits

(9 ... 11)

0x00

Service

4 bits

(12 ... 15)

0x03: SDO response

SDO

Size indicator

BYTE

1 bit

(0)

0x0

Transfer type

1 bit

(1)

0x0

Data set size

2 bits

(2, 3)

0x0

Complete access

1 bit

(4)

0x00: The entry addressed with an index and

subindex is written.

0x01: The complete object is written. (Is

currently not supported.)

Command specifier

3 bits

(5 ... 7)

0x3: Download response

Index

WORD

2 bytes

Index of the object

Subindex

BYTE

1 byte

Subindex of the object

0x00 or 0x01 if "Complete access" = 0x01.

Reserved

DWORD

4 bytes

0x00

Advertising