8process data transfer – Lenze E94AYCET User Manual

Page 67

Advertising
background image

Lenze · E94AYCET communication module (EtherCAT®) · Communication Manual · DMS 9.0 EN · 02/2014 · TD17

67

8

Process data transfer

8.2

Example of a drive initialisation with the "CiA402" technology application

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Initialisation of device profile objects
SDO write request

0x60C2/1

2

Set time base for interpolation of the position

setpoint.

Time base = 2 x 10

-3

[s] = 2 [ms]

SDO write request

0x60C2/2

0xFD (-3)

SDO write request

0x6092/1

0x10000

Set feed constant for position values in [increments].

One encoder revolution corresponds to 0x10000,

since the feed usually is already converted to

increments in the controller (EtherCAT master).

SDO write request

0x6060

7

Select the "Interpolated position mode" operation

mode.

Initialisation of manufacturer-specific objects
SDO write request

0x55A4

0x10000

Configure touch probe for the "Homing mode"

operating mode in C02651.

Touch probe is triggered by motor encoder zero

pulse.

SDO write request

0x55AF

2

Select "2" for "Homing mode" operating mode in

C02640.

1.Motion in positive direction with profile data set

1.

2.Reversing on positive travel range limit switch.

3.The positive edge of the reference switch

activates profile data set 2 for a further reference

search.

4.Negative edge of the reference switch enables

home position detection.

5.The following positive edge of the encoder zero

pulse/touch probe sensor sets the reference

(0x607C).

6.Absolute positioning to target position (C02643)

with profile data set 2 (if 0x60FB/7 = "0").

SDO write request

0x5B9F

4

Write request to code C01120 (sync source) for drive

synchronisation.

Change of the communication status
NMT

-

-

Switch drive to "Operational" communication status.

Cyclic process data exchange
PDO1-Rx to the drive

-

-

Transmit the process data to the drive according to

PDO mapping.

Sync

-

-

Process data synchronisation

PDO1-Tx from the drive

-

-

Receive process data from the drive according to PDO

mapping.

Communication service

Object

Value

Info

Advertising