7

Data transfer

7.3

EtherCAT state machine

58

Lenze · E94AYCET communication module (EtherCAT®) · Communication Manual · DMS 9.0 EN · 02/2014 · TD17

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

Possible errors at the state transitions are shown in

C13879

/

C14879

. Additionally, an error

message is entered in the "AL Status Code" EtherCAT register (see below).

Diagnostics with the »Engineer«

( 88)

EtherCAT status displays

( 85)

AL Status Code
Information about how the "AL Status Code" EtherCAT register (address 0x0134:0x0135) can be

accessed can be found in the documentation of the EtherCAT master.
These error messages can be entered in the "AL Status Code" register:

AL Status Code

[hex]

Description

0x0000

No fault

0x0011

Invalid status change requested

0x0012

Unknown status requested

0x0013

"Bootstrap" status is not supported

0x0016

Invalid mailbox configuration "Pre-operational"

0x001A

Synchronisation error

0x001B

Sync manager watchdog

0x001D

Invalid output data configuration

0x001E

Invalid input data configuration

0x002B

Invalid input and output data

0x0030

Invalid configuration of DC synchronisation

0x9001

Firmware watchdog error

0x9002

Mapping error