13 parameter reference, C00615 | resp. to imp. device conf, C00636 | resp. to new module in mxi1 – Lenze E94AYCET User Manual

Page 94: Parameter reference

Advertising
background image

13

Parameter reference

13.1

Communication-relevant parameters of the standard device

94

Lenze · E94AYCET communication module (EtherCAT®) · Communication Manual · DMS 9.0 EN · 02/2014 · TD17

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

13

Parameter reference

This chapter supplements the parameter list and the table of attributes contained in the reference

manual and in the »Engineer« online help for the Servo Drive 9400 with the parameters of the

E94AYCET (EtherCAT) communication module.

13.1

Communication-relevant parameters of the standard device

This chapter lists the communication-relevant parameters of the Servo Drive 9400 in numerically

ascending order.

C00615

C00636

Reference manual/online help for the Servo Drive 9400
Here you will find general information about parameters.

Parameter | Name:

C00615 | Resp. to imp. device conf.

Data type: UNSIGNED_32

Index: 23960 = 0x5D98

Response to incorrect device configuration
Selection list

1 Error
3 Quick stop by trouble
4 Warning locked
6 Information
0 No response

Subcodes

Lenze setting

Info

C00615/1

0: No response

Reserved

C00615/2

1: Fault

Resp. to imp. module in MXI1

C00615/3

1: Fault

Resp. to imp. module in MXI2

C00615/4

0: No response

Reserved

C00615/5

0: No response

Reserved

Read access  Write access  CINH  PLC-STOP  No transfer

Parameter | Name:

C00636 | Resp. to new module in MXI1

Data type: UNSIGNED_32

Index: 23939 = 0x5D83

Response when a new module has been inserted in module slot 1 of the standard device.
Selection list

(Lenze setting printed in bold)

1 Error
6 Information
5 Warning
4 Warning locked
3 Quick stop by trouble
0 No response

Read access  Write access  CINH  PLC-STOP  No transfer