2 network topology, Network topology, Network topology ( 25) – Lenze E94AYCET User Manual

Page 25: 5installation, Msd sd sd, Ms sd sd m

Advertising
background image

Lenze · E94AYCET communication module (EtherCAT®) · Communication Manual · DMS 9.0 EN · 02/2014 · TD17

25

5

Installation

5.2

Electrical installation

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

5.2.2

Network topology

An EtherCAT frame is sent through a pair of wires from the master to the slaves. The frame is

forwarded from slave to slave until it has passed through all the devices. Finally, the last slave

returns the frame to the master through a second pair of wires. In this way, EtherCAT always forms

a logic ring topology, irrespective of the topology used.

Line topology

[5-4]

Line topology

The devices are interconnected successively.
In order to ensure trouble-free operation, it is required to assign and wire the EtherCAT inputs (IN)

and EtherCAT outputs (OUT) correctly.
The receiving line is plugged into socket X246 (IN), the forwarding line into socket X247 (OUT).
The direction of data transmission is from the master to the slaves.

Tip!
The termination of the last EtherCAT node is effected automatically by the slave.

Switch topology

[5-5]

Switch topology

The wiring can also be carried out in a star structure via an appropriate switch. For this, observe the

additional runtimes.

E94AYCET006

M = master
SD = slave device

M

SD

SD

SD

IN

IN

OUT

IN

OUT

E94AYCET007

M = master
S = switch
SD = slave device

M

S

SD

SD

M

IN

IN

Advertising