6

Commissioning

6.5

Establishing an online connection with the »Engineer«

42

Lenze · E94AYCET communication module (EtherCAT®) · Communication Manual · DMS 9.0 EN · 02/2014 · TD17

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

How to configure an online connection to a field device which is connected to the Lenze

Controller via EtherCAT:

1. Go to the "Communication path" dialog box and select the entry "Gateway controller ->

EtherCAT" from the "Bus connection" list field.

2. Click Search/Enter....

The "Gateway Controller -> Set up EtherCAT bus" dialog box is shown:

3. Enter the IP address of the controller.

By clicking the Ping button, you can carry out a simple test which verifies whether a device

can actually be reached via the IP address set.

4. Click OK.

• The "Enter IP address" dialog box is closed.
• In the Device access path column of the "Communication path" dialog box, the

corresponding device access path is shown

(e.g. "IPC:172_31_207_254.ECAT.ecat1.dev1001.").