Lenze · E94AYCET communication module (EtherCAT®) · Communication Manual · DMS 9.0 EN · 02/2014 · TD17

43

6

Commissioning

6.5

Establishing an online connection with the »Engineer«

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

6.5.2

Gateway controller -> configure EtherCAT ADS (Beckhoff)

The Gateway EtherCAT ADS bus connection makes it possible to establish an online connection to a

Lenze drive that is connected to a Beckhoff controller via EtherCAT (gateway function).

[6-3]

Example: EtherCAT bus system with a Beckhoff controller as Gateway

How to configure an online connection to a field device which is connected to a Beckhoff

controller via EtherCAT:

1. Highlight the project root

in the project.

Alternatively: Create a new project or carry out a fieldbus scan.

2. Execute the menu command Insert Insert device detected online.
3. Select Gateway Controller -> EtherCAT ADS as bus connection.
4. Configure access data:

• Configure the access data applicable to the controller via the Insert address button.
• The Search button initiates the controller to display the fieldbus nodes connected to the

EtherCAT segment.