C14540 | mapping entries tpdo-10, C14784 | active tpdo channel, C14789 | no. of tpdo mapping entries – Lenze E94AYCET User Manual

Page 124: C14540, C14784, C14789/1, C14789/10, 13 parameter reference

Advertising
background image

13

Parameter reference

13.3

Parameters of the communication module for slot MXI2

124

Lenze · E94AYCET communication module (EtherCAT®) · Communication Manual · DMS 9.0 EN · 02/2014 · TD17

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C14540

C14784

C14789

Parameter | Name:

C14540 | Mapping entries TPDO-10

Data type: UNSIGNED_64

Index: 10035 = 0x2733

This code is used device-internally and must not be written by the user!

Subcodes 1 ... 32 specify the mapping for the TPDO channel 10.

• Servo Drives 9400 exclusively support mapping objects with a data length of 8 bits (1 byte) or a multiple of this

value. Incompatible objects must be mapped to variables with a compatible data length.

• The master must have the same mapping entries as the slave.

Structure of the mapping codes ( 64)

Value is bit-coded:

Info

Bit 0 Bit 0

... ...

Bit 63 Bit 63

Subcodes

Lenze setting

Info

C14540/1

0

1. Mapping entry TPDO-10 (I-1A09.01)

...

...

...

C14540/32

0

32. Mapping entry TPDO-10 (I-1A09.20)

Read access  Write access  CINH  PLC-STOP  No transfer  PDO_MAP_RX  PDO_MAP_TX  COM  MOT

Parameter | Name:

C14784 | Active TPDO channel

Data type: UNSIGNED_8

Index: 9791 = 0x263F

This code is used device-internally and must not be written by the user!

Selection of the active TPDO channel
Selection list

Info

0 No TPDO
1 TPDO-1 (I-1A00)

... ...

10 TPDO-10 (I-1A09)

Subcodes

Lenze setting

Info

C14784/1

1: TPDO-1 (I-1A00)

Active TPDO channel

Read access  Write access  CINH  PLC-STOP  No transfer  PDO_MAP_RX  PDO_MAP_TX  COM  MOT

Parameter | Name:

C14789 | No. of TPDO mapping entries

Data type: UNSIGNED_8

Index: 9786 = 0x263A

This code is used device-internally and must not be written by the user!

Subodes 1 ... 10 specify the number of valid mapping entries of TPDO channels 1 ... 10 (valid subcodes in

C14531

...

C14540

).

Setting range

(min. value | unit | max. value)

0

32

Subcodes

Lenze setting

Info

C14789/1

0

No. of mapping entries for TPDO-1

...

...

...

C14789/10

0

No. of mapping entries for TPDO-10

Read access  Write access  CINH  PLC-STOP  No transfer  PDO_MAP_RX  PDO_MAP_TX  COM  MOT

Advertising