Diagnostics

11.1

LED status displays

86

Lenze · E94AYCET communication module (EtherCAT®) · Communication Manual · DMS 9.0 EN · 02/2014 · TD17

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

ERR

red

off

No fault

blinking

The configuration is invalid/faulty.

blinking once

(single flash)

• A non requested state change has occurred. (The slave application

has autonomously changed the EtherCAT status.)

• Synchronisation error (The EtherCAT node automatically changes to

the "Safe-operational" state.)

blinking twice

(double flash)

An "Application Watchdog Timeout" or a "Sync Manager Watchdog

Timeout" has occurred.

LED

Colour

State

Description

200 ms

200 ms

1000 ms

200 ms

200 ms

1000 ms

200 ms

200 ms

1000 ms

200 ms

200 ms

200 ms

200 ms