1 dc configuration in the master, Dc configuration in the master, 6commissioning – Lenze E94AYCET User Manual
Page 36
6
Commissioning
6.4
Synchronisation with "Distributed Clocks" (DC)
36
Lenze · E94AYCET communication module (EtherCAT®) · Communication Manual · DMS 9.0 EN · 02/2014 · TD17
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
6.4.1
DC configuration in the master
By default, the application of the DC synchronisation is deactivated in the device description
Parameterise the DC synchronisation in the EtherCAT configuration software (e.g. »PLC Designer«,
»TwinCAT«).
Set the synchronisation cycle time in the master. It is mainly defined by the processing time of the
master and the slaves.
Note!
The synchronisation cycle time ...
• must be an integer multiple of 1 ms;
• may be maximally 15 ms.