C14484 | active rpdo channel, C14489 | no. of rpdo mapping entries, C14531 | mapping entries tpdo-1 – Lenze E94AYCET User Manual

Page 119: C14531, C14484, C14489/1, C14489/10, 13 parameter reference

Advertising
background image

Lenze · E94AYCET communication module (EtherCAT®) · Communication Manual · DMS 9.0 EN · 02/2014 · TD17

119

13

Parameter reference

13.3

Parameters of the communication module for slot MXI2

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

C14484

C14489

C14531

Parameter | Name:

C14484 | Active RPDO channel

Data type: UNSIGNED_8

Index: 10091 = 0x276B

This code is used device-internally and must not be written by the user!

Selection of the active RPDO channel
Selection list

Info

0 No RPDO
1 RPDO-1 (I-1600)

... ...

10 RPDO-10 (I-1609)

Subcodes

Lenze setting

Info

C14484/1

1: RPDO-1 (I-1600)

Active RPDO channel

Read access  Write access  CINH  PLC-STOP  No transfer  PDO_MAP_RX  PDO_MAP_TX  COM  MOT

Parameter | Name:

C14489 | No. of RPDO mapping entries

Data type: UNSIGNED_8

Index: 10086 = 0x2766

This code is used device-internally and must not be written by the user!

Subcodes 1 ... 10 specify the number of valid mapping entries of RPDO channels 1 ... 10 (valid subcodes in

C14231

...

C14240

).

Setting range

(min. value | unit | max. value)

0

32

Subcodes

Lenze setting

Info

C14489/1

0

No. of mapping entries for RPDO-1

...

0

...

C14489/10

0

No. of mapping entries for RPDO-10

Read access  Write access  CINH  PLC-STOP  No transfer  PDO_MAP_RX  PDO_MAP_TX  COM  MOT

Parameter | Name:

C14531 | Mapping entries TPDO-1

Data type: UNSIGNED_64

Index: 10044 = 0x273C

This code is used device-internally and must not be written by the user!

Subcodes 1 ... 32 specify the mapping for the TPDO channel 1.

• Servo Drives 9400 exclusively support mapping objects with a data length of 8 bits (1 byte) or a multiple of this

value. Incompatible objects must be mapped to variables with a compatible data length.

• The master must have the same mapping entries as the slave.

Structure of the mapping codes ( 64)

Value is bit-coded:

Info

Bit 0 Bit 0

... ...

Bit 63 Bit 63

Subcodes

Lenze setting

Info

C14531/1

0

1. mapping entry TPDO-1 (I-1A00.01)

...

...

...

C14531/32

0

32. mapping entry TPDO-1 (I-1A00.20)

Read access  Write access  CINH  PLC-STOP  No transfer  PDO_MAP_RX  PDO_MAP_TX  COM  MOT