Rockwell Automation 440C Guardmaster 440C-CR30 Configurable Safety Relay User Manual User Manual

Page 108

Advertising
background image

108

Rockwell Automation Publication 440C-UM001C-EN-P - November 2014

Chapter 15

Troubleshooting

Remove the fault

The Modbus address 000505 goes LO immediately, showing that the fault
was removed.

Modbus address 000393 (Bit 0 of SMF1) remains HI.

On the CCW Logic tab, both the E-stop and gate logic blocks continue to
show red color.

The safety output remains off.

Cycle the E-stop.

Modbus address 000393 (Bit 0 of SMF1) goes LO.

On the CCW Logic tab, the E-stop block turns green, and the gate block
remains red,

Cycle the gate.

On the CCW Logic tab, the gate block turns green.

The safety system is back to an operating state and waiting for the reset button to
be pressed.