Compatibility, Work with a locked safety relay, Upload from a password-protected safety relay – Rockwell Automation 440C Guardmaster 440C-CR30 Configurable Safety Relay User Manual User Manual

Page 110: Connect to a password-protected safety relay, Download to a password-protected safety relay, Compatibility work with a locked safety relay

Advertising
background image

110

Rockwell Automation Publication 440C-UM001C-EN-P - November 2014

Chapter 16

Security and Password

Compatibility

The Safety Relay Password feature is supported on:

Connected Components Workbench version7 and later

Guardmaster 440C safety relays with revision 7 or later firmware

Users with earlier versions of the software and/or hardware are advised to
upgrade the software and firmware. See

Upgrade the Firmware on page 141

for

instruction on firmware upgrades.

Work with a Locked Safety
Relay

The following workflows are supported on compatible Guardmaster 440C safety
relays (firmware revision 7 or later) and CCW version 7 or later.

Upload from a Password-Protected Safety Relay

1.

Launch the CCW software project with your Guardmaster 440C safety
relay configuration.

2.

Double-click the Guardmaster 440C safety relay in the Project
Organizer to open the Safety Relay workspace.

3.

Select Upload from the pull-down menu in the safety relay header.

4.

Select the target safety relay in the Connection Browser.

5.

When requested, provide the safety relay password.

Connect to a Password-Protected Safety Relay

1.

Launch the CCW software project with your Guardmaster 440C safety
relay configuration.

2.

Double-click the Guardmaster 440C safety relay in the Project
Organizer to open the Safety Relay workspace.

3.

Select Connect from the pull-down menu in the safety relay header.

4.

Select the target safety relay in the Connection Browser.

5.

When requested, provide the safety relay password.

Download to a Password-Protected Safety Relay

1.

Launch the CCW software project with your Guardmaster 440C safety
relay configuration.

2.

Double-click the Guardmaster 440C safety relay in the Project
Organizer to open the Safety Relay workspace.

3.

Select Download from the pull-down menu in the safety relay header.

4.

Select the target safety relay in the Connection Browser.

5.

When requested, provide the safety relay password.

Advertising