Rockwell Automation Publication 440C-UM001C-EN-P - November 2014

63

Safety Monitoring Functions

Chapter 9

Figure 62 - Example Schematic for a Safety Mat

SensaGuard

The SensaGuard™ function block sets the parameters for interlocks having dual
OSSD outputs. In the CCW, click and drag (or double-click) the block to an
available Safety Monitoring Function spot. This block can be used for other
devices with OSSD outputs.

Figure 63 - SensaGuard Function Block

The available input selections for the SensaGuard inputs are:

EI_00…EI_11 (embedded input terminals 00…11)

MP_12…MP_17 (multi-purpose terminals 12…17)

You can use the default Discrepancy Time (See

Discrepancy Time on page 41

)

and Input Filter (See

Input Filter on page 39

) or choose to modify these settings.

Figure 64 - Example Schematic of a SensaGuard Interlock