Rockwell Automation Publication 440C-UM001C-EN-P - November 2014

Appendix A

Specifications

The evaluation method of the input or output signal depends on the
configuration of the SMF and SOF in CCW and the wiring of the sensor.

Table 25

shows typical evaluation functions and required settings to be enabled.

Table 25 - Evaluation Method

Evaluation Method

Configuration

Applicable for

Multi-channel signal evaluation

Inputs: 2 N.C., 2 OSSD, 3 N.C.

(1)

or

3 OSSD

(1)

SMF:
Emergency Stop
Enabling Switch
Gate Switch
Light Curtain
Two Hand Control
Alternative Device
Muting: Light Curtain settings
Muting: Override settings

Test pulse evaluation

Test Pulses: 1 or 2 sources, or 3
sources

(1)

: >0

SMF:
Emergency Stop
Enabling Switch
Gate Switch
Two Hand Control
Alternative Device
Muting: Override settings

Input Discrepancy Time

Discrepancy Time

(2)

: >0

Range: 0.05…3 s

SMF:
Emergency Stop
Enabling Switch
Gate Switch
Light Curtain
Two Hand Control
Alternative Device
Muting: Light Curtain settings
Muting: Override settings

Two Hand Discrepancy Monitoring

Default: 0.5 s
The maximum amount of time
between activation of Hand 1 and
Hand 2 to enable SMF

SMF
Two Hand Control

Muting Sequence

Muting Type: 2 Sensor T-Type, 2
Sensor L-Type, 4 Sensor
Defines the type of muting
application and thus the valid
sequence of clearing or blocking the
muting sensors and protective
device.

SMF
Muting