Rockwell Automation Publication 440C-UM001C-EN-P - November 2014

51

Safety Monitoring Functions

Chapter 9

Light Curtain

The Light Curtain function block sets the parameters for light curtains that have
dual OSSD outputs. In the CCW, click and drag (or double-click) the block to
an available Safety Monitoring Function spot. This block can be used for other
devices, like laser scanners, with OSSD outputs.

Figure 43 - Light Curtain Function Block

The available input selections for the Light Curtain inputs are:

EI_00…EI_11 (embedded input terminals 00…11)

MP_12…MP_17 (multi-purpose terminals 12…17)

You can use the default Discrepancy Time and Input Filter or choose to modify
these settings.

Figure 44 - Example Schematic of a Light Curtain

+24V DC

24V Com

05

CR30

02

01

00

03 04

A1

15

20 21

16

06

18

A2

07

19

08

10 11

12 13 14

09

17

OSSD1

Receiver

+

+

-

-

Transmitter

OSSD2