Specifications

SIL Rating

The CR30 meets the requirements of SIL CL 3 in accordance with
IEC/EN 61508.

Table 19 - SIL Rating

Performance Level/Category

The performance Level of the safety function is dependent on the structure of all
devices that comprise the safety function.

The CR30 is capable of being used in safety systems meeting up to Category 4
and Performance Level PLe in accordance with ISO 13849-1.

Table 20 - Performance Level/Category

Safety Integrity Level Claim Limit

3

PFD

1,76 10-3 (whole safety function)

PFH

1 10-8

Mode of Operation

High-demand mode

Safety Related Subsystems

Type B (use of programmable / complex components)

Hardware Fault Tolerance

HFT = 1 (two channel system)

Safe Failure Fraction

90…99%

Category

Up to 4

Performance Level

Up to e