Connecting the Human Interface Module to the Controller

Figure 46

shows the connection of the SMC Flex controller to a human interface

module.

Table 11

provides a description of each port.

See

Figure 21 on page 31

or

Figure 24 on page 34

for the control wiring diagram

that enables start-stop control from a human interface module.

Figure 46 - SMC Flex Controller with Human Interface Module

Table 11 - SMC Flex Controller with Human Interface Module

HIM Control Enable

To enable motor control from a connected human interface module, follow the
procedure below with the connected human interface module’s programming
keys.

The Bulletin 20-HIM-LCD human interface modules with control panels can
start and stop the SMC Flex controller. However, the factory default settings
disable control commands other than Stop through the serial communication
port.

TIP

The SMC Flex only supports the use of DPI communication modules and DPI
HIM Modules. Scanport devices are not supported by the SMC Flex.

Port #

Description

1

Unused – Not available for use

2

First 20-HIM connected to SMC Flex

3

Second 20-HIM connected to SMC Flex

5

DPI Communication Board port

Port 5 – DPI Communications

Port 2

Ports 2 and 3 when two HIMs
are connected with a splitter