Figure 43 - menu structure hierarchy – Rockwell Automation MV SMC Flex Motor Controller (for Series K or later) User Manual

Page 83

Advertising
background image

Rockwell Automation Publication 1560E-UM051F-EN-P - June 2013

73

Programming

Chapter 4

Figure 43 - Menu Structure Hierarchy

Motor

Protection

Communications

Utility

Set Up

Monitoring

Metering

Volts Phase A-B
Volts Phase B-C
Volts Phase C-A
Current Phase A
Current Phase B
Current Phase C
Watt Meter
Megawatt Hours
Elapsed Time
Meter Reset
Power Factor
Mtr Therm Usage
Motor Speed

Esc

Linear List

Parameter

(1),(3)

Basic

SMC Option
Motor Connection
Line Voltage
MV Ratio
Starting Mode
Ramp Time
Initial Torque
Cur Limit Lvl
Kickstart Time
Kickstart Lvl
Stop Input
Option 1 Input
Option 2 Input
Stop Mode
Stop Time
Braking Current
Overload Class
Service Factor
Motor FLC
CT Ratio
Overload Reset
Aux1 Config
Aux2 Config
Aux3 Config
Aux4 Config
Backspin Timer
Parameter Mgt.

(4)

Dual Ramp (Option 2
Input = Dual Ramp)

Starting Mode 2
Ramp Time 2
Initial Torque 2
Cur Limit Lvl 2
Kickstart Time 2
Kickstart Lvl 2
Parameter Mgt.

(4)

Preset SS (Option 2
Input = Preset SS)

Slow Speed Sel
Slow Speed Dir
Slow Speed Acc
Slow Running Cur
Parameter Mgt.

(4)

(Option 2 Input =
Accu-Stop)

Braking Current
Slow Speed Sel
Slow Speed Dir
Slow Accel Cur
Slow Running Cur
Stopping Current
Parameter Mgt.

(4)

Overload

Overload Class
Service Factor
Motor FLC
Overload Reset
Overload A Lvl
Parameter Mgt.

(4)

Underload

Underload F Lvl
Underload F Dly
Underload A Lvl
Underload A Dly
Parameter Mgt.

(4)

Undervoltage

Undervolt F Lvl
Undervolt F Dly
Undervolt A Lvl
Undervolt A Dly
Parameter Mgt.

(4)

Overvoltage

Overvolt F Lvl
Overvolt F Dly
Overvolt A Lvl
Overvolt A Dly
Parameter Mgt.

(4)

Unbalance

Unbalance F Lvl
Unbalance F Dly
Unbalance A Lvl
Unbalance A Dly
Parameter Mgt.

(4)

Jam

Jam F Lvl
Jam F Dly
Jam A Lvl
Jam A Dly
Parameter Mgt.

(4)

Stall

Stall Dly
Parameter Mgt.

(4)

Ground Fault

Gnd Flt Enable
Gnd Flt Lvl
Gnd Flt Dly
Gnd Flt Inh Time
Gnd Flt A Enable
Gnd Flt A Lvl
Gnd Flt A Dly
Parameter Mgt.

(4)

PTC

PTC Enable
Parameter Mgt.

(4)

Phase Reversal

Phase Reversal
Parameter Mgt.

(4)

Restart

Starts Per Hour
Restart Attempts
Restart Dly
Parameter Mgt.

(4)

Comm Masters

Logic Mask
Parameter Mgt.

(4)

Data Links

Data In A1
Data In A2
Data In B1
Data In B2
Data In C1
Data In C2
Data In D1
Data In D2
Data Out A1
Data Out A2
Data Out B1
Data Out B2
Data Out C1
Data Out C2
Data Out D1
Data Out D2
Parameter Mgt.

(4)

Language

Language
Parameter Mgt.

(4)

Motor Data

Motor Flc
Motor ID
CT Ratio
MV Ratio
Parameter Mgt.

(4)

Linear LIst

All parameters
Parameter Mgt.

(4)

(1) Depending upon SMC option selected, some parameters may not appear in product display.
(2) Steps back one level
(3) For further information on parameters, refer to

Appendix B

.

(4) For further information on parameter management, refer to

Parameter Management on page 76

.

(2)

Advertising