6ć21, Set mode – Rockwell Automation 6008-SV2R VMEbus remote I/O Scanner User Manual

Page 102

Advertising
background image

Chapter

Operating in SVĆSuperset Mode

6

6Ć21

SET MODE changes the operating mode of the scanner.

not used

Byte offset

(Hex)

0202

0204

0206

-021B

021E

Name

021C

00H returned means the command was

successful. Any other value indicates

an error.

20H is both sent and returned.

Mode

01 = Program

02 = Test

04 = Run

Bit 7 = semaphore

not used

not used

0220

channel A

control/status

not used

mode

channel A

general data

not used

0222

-02FF

semaphore

command

confirmation

0203

0205

not used

not used

021D

0220

The VME master processor writes 20 (hex) to the command byte. Then
the VME master processor writes this parameter to the selected channel’s
general data area:

Byte

offset:

Parameter:

Description:

0220

mode

Write one of these values (hex):
01

Program mode

02

Test mode

04

Run mode

Values 00, 03, and 05-FF are reserved. If you write a reserved value

to this field, the scanner writes an illegal confirmation error (16H) in the

confirmation status byte.

SET MODE

command byte 20

description

parameters

Advertising