Chapter
Operating in SVĆCompatible Mode
5
5Ć2
Figure 5.1
General structure of global RAM for SVĆcompatible mode
byte offset
(hex)
byte offset
(hex)
Channel A
Channel B
000
output image table
64 words
100
080
120
1000
FC0
1080
1100
1FC0
1120
input image table
64 words
control/status area
16 words
general data area
1872 words
interrupt/VME ID area
32 words
output image table
64 words
input image table
64 words
control/status area
16 words
general data area
1872 words
interrupt/VME ID area
32 words
(6008ĆSV2R scanner only)
The physical address is the base address plus the byte offset.
Important: Add 1000 (hex) to channel A addresses to get the
corresponding addresses for channel B.