Chapter

Operating in SVĆSuperset Mode

6

6Ć42

The VME master processor writes 07 (hex) to the command byte. Then
the VME master processor writes these parameters to the control status
area of the selected channel:

Byte

offset:

Parameter: Description:

0207

continuous blockĆtransfer address

The module address is the address of the I/O module that is to receive the block

data. It contains the rack (0-15), group (0-7), and slot (0 or 1) numbers of the I/O

module. See Figure 6.17 on page 6Ć43

0209

continuous blockĆtransfer tag

The VME master processor writes a number (0-15) that is an index into the

continuous block transfer write table. Only the lower byte is used.

020A

continuous blockĆtransfer

status ID

Specifies the VME status ID used when the blockĆtransfer is completed. See

Figure 6.18 on page 6Ć43.

020B

continuous blockĆtransfer

interrupt level

Specifies the VME interrupt level used when the blockĆtransfer is completed. See

Figure 6.18 on page 6Ć43.

021F

continuous blockĆtransfer

length of data

The VME master processor writes the number of words of continuous

blockĆtransfer data (0-64).
Use the value 0 to let the I/O module determine how many words the scanner can

write. When the blockĆtransfer completes, the 0 is replaced by the actual number

of words written.

0301

continuous blockĆtransfer tag
READ ONLY

configure this parameter at byte offset 0209 (see above)

0303

continuous blockĆtransfer address
READ ONLY

configure this parameter at byte offset 0207 (see above)

0305

length of data
READ ONLY

configure this parameter at byte offset 021F (see above)

0306

continuous blockĆtransfer

status ID
READ ONLY

configure this parameter at byte offset 020A (see above)

0307

continuous blockĆtransfer

interrupt level
READ ONLY

configure this parameter at byte offset 020B (see above)

0309

continuous blockĆtransfer

scanner flag

Used for Peterson semaphore. See sample code in chapter 8.

030B

continuous blockĆtransfer

VME flag

Used for Peterson semaphore. See sample code in chapter 8.

030D

continuous blockĆtransfer

turn flag

Used for Peterson semaphore. See sample code in chapter 8.

030F

continuous blockĆtransfer

status
READ ONLY

Indicates the status of the continuous blockĆtransfer.

0100 = block transfer disabled

0200 = block transfer pending

0400 = block transfer sent

0800 = block transfer received

0310-0350 continuous blockĆtransfer

write/read data

(64 words)

Contains as many as 64 words of write or read data

parameters

Advertising